XPERT 90

Microfocus X-Ray System For Science & Research

The XPERT 90 TM is a self-contained, shielded cabinet X-ray system designed to meet imaging requirements for various micro focus X-ray imaging requirements in Science and Research. These applications include:
  •   Agriculture Semiconductors BGA Inspection
  •   Botany Marine Biology Pharmaceuticals
  •   Granaries Forestry Small Animal Research

  • With its small focal spot x-ray source and adjustable sample positioning capability, the XPERT 90 TM provides variable magnification and maneuverability for increased visibility and sharpness of detail.

    The XPERT 90 TM is easy and simple to operate. Its compact size, low weight, and standard AC power requirement allow it to be conveniently located and operated in any laboratory or field setting.
    • Ease of operation
    • No radioactive isotopes used
    • Convenience and space savings
    • Shielded, radiation safe enclosure
    • Simple to operate and maintain
    • Electrically operated turntable
    • Control using included RS-232
    • Output Voltage 0 to 160 kV
    • Output Current 25 mA at 160 kV
    • Output Voltage Regulation 1% of rated output for a 10% change in line and load
    • Active Power factor Correction - > 0.98
    • X-ray Tube - Stationary anode, Tungsten target, metal-ceramic with beryllium window
    • Beam Angle - 45° divergence
    • Cooling Forced Air based integrated heat exchanger
    • Higher Output Sources Available - Contact us for sources with output up to 450 kV
    • Specifications are subject to change without notice.
    • Exposure Time - Manual (continuous) or variable from 1 sec to 99.9 minutes
    • Source to Object Distance - 5" to 39" (127 mm to 991 mm)
    • Maximum Coverage - 30" (762 mm)
    • External Dimensions - 62"H x 36"W x 39"D (1575 mm x 915 mm x 990 mm)
    • Electrically Operated Specimen Turntable - 2 RPM provided to improve dose uniformity.
    • Power Requirements - 220 VAC 50/60 Hz +/- 10%
    • Additional Sizes Contact us for cabinets with different dimensions and additional features
    • Energy Range : 20-90 kV
    • Tube Current : 300 µ A
    • Focal Spot size : 4 microns
    • Window Filtration : 0.005" beryllium
    • X-ray Coverage : 40 degrees
    • Power : 90-250 VAC, 50/60 Hz, 400VA
    • Size : 18"w x 22"d x 30"h
    • Weight : 150 lbs.
    • Micro focus sources with output up to 160 kV available
    With its complete shielding and other required radiation safety features, the XPERT 90 TM is in full compliance with Federal and State requirements for radiation safety. It does not require licensing and typically only requires registration with the state in which it is installed.